Some factories may temporarily stop air compressor operation due to production adjustment, so how to properly handle the shutdown air compressor?When screw air compressor is shut down for a long time, the following methods should be strictly followed according to the length of shutdown time, especially in the season or area where temperature is lower than 0 degrees and high humidity.
Treatment methods for screw air compressor stopping for more than 1 month:
1) Pack the air compressor controller, distribution box and other electrical equipment with plastic or oil paper to prevent gas intrusion;
2) When the air compressor is shut down, the water in the oil cooler and the rear cooler should be completely drained to avoid freezing and cracking damage of the cooler under low temperature conditions.
3) If there are any faults before the air compressor stops, it should be repaired and placed again so as not to need emergency use in the future.
4) Drain condensate from oil and gas barrel, oil cooler and rear cooler two or three days after shutdown of air compressor;
In addition to the above procedures, the following procedures shall be carried out when the screw air compressor has been shut down for more than 3 months:
1) Close all openings of the air compressor to prevent moisture and dust from entering.
2) Replace lubricant of air compressor before shutdown and run for 30 minutes. Drain condensate from air drum and oil cooler two or three days later.
3) Drain condensate completely;
4) Put the air compressor in a place with little dust and dry air.