Rated inlet pressure: 0.7MPa (06mpa-1.0mpa is allowed)
Rated intake air temperature: 10 ° c-30 ° C (2 ° C-40 ℃)
Dew point of finished gas: - 20 ~ - 40 ℃
Ambient temperature: ≤ 45 ℃
Pressure loss: ≤ 0.02MPa
Regeneration mode: no heat regeneration
Adsorbent: activated alumina
Oil content of intake air: ≤ 0.1mg/m3
Average regeneration gas consumption: 8-14% gas consumption
Installation method: there is no foundation indoors, the concrete is flat, and the surrounding space is not less than 1m2
Control mode: full electronic programmable time control (dew point control) can be selected
MC certified pressure gauge
Inlet silencer
Intelligent control interface
Tse dew point energy saving control (optional configuration)
Pneumatic control element
Gas diffusion device